TES-W180-M12-WV-IP67

EN50155 8-port Unmanaged Ethernet Switch, IP-67 grade

-40_75c.pngen50155.pngip67.pngisolation.png

Description

The ORing TES-W180-M12-WV-IP67 is an EN 50155-compliant 8-port unmanaged industrial Ethernet switch designed for railway rolling stock and onboard network applications. Featuring eight 10/100Base-T(X) M12 Ethernet ports, the switch provides reliable connectivity in environments subject to vibration, shock, dust, and moisture.

Its rugged IP67-rated aluminum enclosure, 24/110 VDC power input options, and wide operating temperature range of -40°C to +75°C make it suitable for demanding railway and transportation environments. With compliance to EN 50155 and EN 50121-4 standards, the TES-W180-M12-WV-IP67 delivers durable, low-maintenance Ethernet connectivity for mission-critical onboard networks.

Features

  • EN 50155-compliant unmanaged Ethernet switch for railway rolling stock applications
  • 8 × 10/100Base-T(X) Fast Ethernet ports with rugged M12 connectors
  • IP67-rated aluminum enclosure for protection against dust and water ingress
  • Shock- and vibration-resistant design for demanding railway environments
  • Supports 24/110 VDC power input options with overload and reverse polarity protection
  • Wide operating temperature range from -40°C to +75°C

Physical ports

Total Ethernet Ports8
100M Ethernet Ports8 x 10/100Base-T(X) M12

Power

IsolationPresent
Power consumption (Typ.)3 Watts
Connector4-pin A-coded M12 male connector
Power Input24/110VDC Power Input
Overload current protectionPresent
Reverse polarity protectionPresent

Physical Characteristic

EnclosureIP-67
Dimensions (mm)62 (W) x 30 (D) x 200 (H) mm
(2.44 x 1.18 x 7.874 inches)
Weight (g)N.W: 759g / G.W: 940g

Technology

Ethernet StandardsIEEE 802.3 for 10Base-T, IEEE 802.3u for 100Base-TX, IEEE 802.3x for Flow control
MAC Table2K
ProcessingStore-and-Forward
Switch PropertiesSwitching Bandwidth: 1.6Gbps, Switching Latency:

Environmental

Storage Temperature-40 to 85oC (-40 to 185oF)
Operating Temperature-40 to 75oC (-40 to 167oF)
Operating Humidity5% to 95% (non-condensing)

Warranty

Warranty5 years

Downloads

DatasheetVersionChecksumRelease DateRelease NoteSize
TES-W180-M12-WV-IP67March 23, 2026314.08 kB

QIGVersionChecksumRelease DateRelease NoteSize
QIG_TES-W180-M12-WV-IP67_v1.0v1.0April 07, 20262.52 MB

Regulatory Approvals

EMCCE EMC (EN 55035, EN 55032), FCC Part 15B, EN 50155 (EN 50121-1, EN 50121-3-2), EN 61000-6-2&4
EMIEN 55032, CISPR32, FCC Part 15B class A
EMSIEC/EN 61000-4-2 ESD, IEC/EN 61000-4-3 RS, IEC/EN 61000-4-4 EFT, IEC/EN 61000-4-5 Surge, IEC/EN 61000-4-6 CS, IEC/EN 61000-4-8 PFMF, IEC/EN 61000-4-11 DIP
ShockIEC 60068-2-27
Free FallIEC 60068-2-31
VibrationIEC 60068-2-6
SafetyEN 62368-1
OtherEN50155 (IEC 61373), EN 50121-4
MTBF869,332 hrs. (Telcordia SR-332 Issue 2, Operating Temperature:25°C)

Dimensions